    Throw me a life line, PID problem.

    I am running a PID controller in front of a laboratory hotplate, I got the hotplate on the very cheap because the thermostat's out.
    (Now the thermostat is completely out).
    I drilled a hole in the plate the same diameter as the thermocouple, got a snug fit.
    I set the PID at 450F to preheat, molds, pit a moldon the plate and started checking the temp with a laser thermometer.
    up to 250F the reading on the PID and the laser thermo match each other, but at 450F indicated on the PID I am getting 350F on the laser thermo.
    Anyone got any ideas?
    Everybody grab a shovel, we got a swamp to drain.

  2. #2
    Boolit Master

    Mike W1's Avatar
    Join Date
    Nov 2008
    Location
    Rural Sumner, IA
    Posts
    1,317
    Just a thought, but maybe when the TC heats up there's some shrinkage with the hole in the plate and you're losing a bit of the contact. That possibly would throw things off. I used a different type TC. Mounted a small piece of aluminum tightly to the aluminum plate on the top of my hot plate. It's tapped for the TC and screws in tight and used the thermal heat grease. Also don't have any faith in the Laser thermo's. When mine crapped out there was never gonna be a replacement.
    Last edited by Mike W1; 04-06-2017 at 12:43 PM.
    Mike

    Benefactor Member NRA
    Life Member Iowa Firearms Coalition
    US Army Vet

    There are two ways to conquer and enslave a nation.
    One is by the sword. The other is by debt.”
    John Adams 1826

  3. #3
    Boolit Buddy
    Join Date
    Nov 2016
    Posts
    101
    It most likely you're controlling the temperature closer to the heater than the surface of the hot plate. Also sometimes the surface finish of the test piece will affect the reading, especially if its shiny. A surface thermocouple is a better was to go.

  4. #4
    Boolit Master
    Join Date
    Jul 2008
    Posts
    4,417
    Where is the actual heating element? Is it bonded to the bottom or interspersed throughout the plate? Could be the thermocouple is real close or butted up to the element.

  5. #5
    Boolit Master
    Join Date
    May 2016
    Location
    Denmark (a greasy little spot in Scandinavia)
    Posts
    815
    IR thermometers dont like shiny surfaces.
    Cant it 15-20degrees and you'll probably get a completely different reading.
    In your case i would trust the PID.

  6. #6
    Boolit Grand Master

    mold maker's Avatar
    Join Date
    Jul 2007
    Location
    Piedmont (Conover) NC
    Posts
    5,429
    The IR thermometer reading is only approx in most instances. It will determine between hot and cold where you can't reach, but reflectivity, the color of a surface, and even oxide on the surface will alter the reading.
    Information not shared. is wasted.

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •  
Abbreviations used in Reloading

BP Bronze Point IMR Improved Military Rifle PTD Pointed
BR Bench Rest M Magnum RN Round Nose
BT Boat Tail PL Power-Lokt SP Soft Point
C Compressed Charge PR Primer SPCL Soft Point "Core-Lokt"
HP Hollow Point PSPCL Pointed Soft Point "Core Lokt" C.O.L. Cartridge Overall Length
PSP Pointed Soft Point Spz Spitzer Point SBT Spitzer Boat Tail
LRN Lead Round Nose LWC Lead Wad Cutter LSWC Lead Semi Wad Cutter
GC Gas Check